OVERCURRENT PROTECTION SCHEMES
What is Overcurrent Protection?
What are the overcurrent protection ?
Protective Relays Overcurrent Instantaneous
Protective Relays Time Overcurrent
Inverse Definite Minimum Time Relay
IDMT Relay Settings
Micom Relay Settings
ACB Relay Settings
Overcurrent is an excess of current—or amperage—in an electrical circuit. ... An overcurrent can be caused by overloading the circuit or by a short circuit, a ground fault, or an arc fault. Circuit breakers and fuses protect circuit wiring from damage caused by overcurrent.
What are the causes of overcurrent?
Possible causes for overcurrent include short circuits, excessive load, incorrect design, an arc fault, or a ground fault. Fuses, circuit breakers, and current limiters are commonly used overcurrent protection (OCP) mechanisms to control the risks.
How can overcurrent be prevented?
Overcurrent protection devices include circuit breakers and fuses. Overcurrent protection devices are meant to protect against the potentially dangerous effects of overcurrents, such as an overload current or a short-circuit current, which creates a fault current
What is overcurrent trip?
Overcurrent protection is protection against excessive currents or current beyond the acceptable current rating of equipment. It generally operates instantly. Short circuit is a type of overcurrent. Magnetic circuit breakers, fuses and overcurrent relays are commonly used to provide overcurrent protection.
What is overcurrent trip?
Overcurrent protection is protection against excessive currents or current beyond the acceptable current rating of equipment. It generally operates instantly. Short circuit is a type of overcurrent. Magnetic circuit breakers, fuses and overcurrent relays are commonly used to provide overcurrent protection.
What is difference between overcurrent and overload?
Overcurrent protection is protection against excessive currents or current beyond the acceptable current rating of equipment. ... Hence, an overload is also type of overcurrent. Overload protection typically operates on an inverse time curve where the tripping time becomes less as the current increases.
What is the difference between overcurrent and earth fault?
Over Current and Earth Fault Protection of Transformer
The over current relays can not distinguish between external short circuit, over load and internal faults of the transformer. ... The normal range of current settings available on IDMT over current relays are 50% to 200% and on earth fault relay 20 to 80%.
Where overcurrent relay is used?
Overcurrent
relay are deployed extensively in the electric power system. They provide protection to important power system equipment including power transformers, generators, transmission lines, loads, motors, busbars etc. They are employed as primary protection as well as backup protection.
What is an earth fault?
Earth Fault is an inadvertent fault between the live conductor and the earth. When earth fault occurs, the electrical system gets short-circuited and the short-circuited current flows through the system. The fault current returns through the earth or any electrical equipment, which damages the equipment.
What is difference between short circuit and overload?
One of the major difference between the short circuit and the overload is that the short circuit occurs because of the fault between the lines or line-to-earth whereas the overload means the equipment draw the excess of current from the supply.
WORKING PRINCIPLE OF OVERCURRENT RELAY
Overcurrent relays are relays that work based on the increase in current that passes through them and can also be based on the specified time setting. ... Basic working principle: An electromechanical relay is an electrical switch actuated by an electromagnet coil.
These are the types of overcurrent relay:
Instantaneous Overcurrent (Define Current) Relay.
Define Time Overcurrent Relay.
Inverse Time Overcurrent Relay (IDMT Relay) Moderately Inverse. Very Inverse Time. Extremely Inverse.
Directional overcurrent Relay.